Installation Diagram; Installation Of The Indoor Unit - McQuay A08019025518 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Indoor Unit
Air Intake Grille
Air Discharge
Louvre
Air Discharge
Grille
Air Intake
Air Discharge
Nozzle
The indoor unit must be installed in such a way so as to
prevent short circuit of the cool discharged air with the hot
return air. Please follow the installation clearance shown in
the figure. Do not place the indoor unit where there could be
direct sunlight shining on it. Also, this location must be
suitable for piping and drainage, and be away from doors or
windows.
50mm
50mm
Air Flow
Direction
Maintenance &
Servicing Space

INSTALLATION DIAGRAM

Indicator Lights
Signal Receiver
Air Intake

INSTALLATION OF THE INDOOR UNIT

50mm
50mm
Installation plate
Marking-offline
Thread
1-3
Air Filters
The refrigerant piping can be routed to the unit in a
number of ways (left or right from the back of the unit), by
using the cut-out holes on the casing of the unit (see figure).
Bend the pipes carefully to the required position in order to
aligned it with the holes. For the right hand and rear side
out, hold the bottom of the piping and then position it to the
required direction (see figure). The condensation drain hose
can be taped to the pipes.
Right & rear side routing
Mount the unit onto the installation plate
Hook the indoor unit onto the upper portion of the
installation plate (Engage the two hooks at the rear top of
the indoor unit with the upper edge of the installation plate).
Ensure that the hooks are properly seated on the
installation plate by moving it to the left and right.
Front Frame
Back Housing
On/Off Switch
Drain Hose
Refrigerant Piping
Outdoor Unit

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wm 301wMwm 301w

Tabla de contenido