SICK WTS26 Instrucciones De Operación página 7

Ocultar thumbs Ver también para WTS26:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
5
ELECTRICAL INSTALLATION
6
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 1: Connections
Wxx26x-
x4
1 = BN
4
2 = WH
3 = BU
4 = BK
5= GY
1
Wxx26x-
1 = BN
2 = BU
3 = not connected
4 = BK
5= WH
6 = GY
7 = not connected
Table 2: DC
WTS26x-
Push-pull
xx161
xx162
PNP
xx861
xx862
1 = BN
2 = WH
3 = BU
4 = BK
Default:
Q
MF
Default:
Q
Q
/C
L1
xH
3
0.14 mm
2
AWG26
2
x9
1
6
2
5
3
4
I
= 4 A
N
xxX6XxxxA00
xx168
xx16A
xx868
xx86A
+ (L+)
MF
- (M)
Q
/C
L1
Q
Test →
no func‐
L+
tion
Q
Q
Q
x5
xI
5
4
3
0.14 mm
AWG26
1
2
xB
7
1
6
2
5
3
4
I
= 6 A
N
xxX6XxxxA0
xx16L
xx16N
xx86L
xx86N
Test →
no func‐
www.sick.co
L+
tion
m 8022709
www.sick.co
Q
Q
m 8022709
8020355.19RH / 15.01.2021 | SICK
Subject to change without notice
2
1-A99
xx16x
xx86x

Publicidad

Tabla de contenido
loading