GB
IRL
1. Activate the shut-off valve [6].
Spraying pressure
1.5 bar
2.0 bar
3.0 bar
Table 2. Linear relationship of: spraying rate and spraying pressure
3. If the spraying pressure decreases more than 0.5 bar from the optimum level, pump
some more.
After Usage
Observe the instructions in the section entitled „Safety".
1. Pull up the red button on the safety valve [9] until all excess pressure is released from
the tank.
2. Lock the pump handle in place [10].
3. Unscrew the pump [1] from the tank [4].
Collect and dispose of the residual liquid according to all applicable laws, require-
ments and regulations. Observe the instructions of the spray product manufacturer!
4. Wipe off the device with a moist cloth.
5. For drying and storing the device, keep the tank and pump separate in a dry place
protected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled „Safety".
After using the device 50 times or at least once a year:
•
Disassemble the pump [1] and grease the diaphragm [13].
•
Grease the O-ring [12]
Observe the legal requirements of your country for accident prevention and
check the device in regular intervals.
If there are no special rules, we recommend you have the device examined
inspection every 5 years.
We would be happy to provide you with an inspection schedule in German or
English.
AUS
USA
Spraying quantity with nozzle 1302
15
NZ
CDN
on the pressure gauge [11].
0.49 l/min
0.56 l/min
0.69 l/min
IND