11

Technical data

11.1

Electrical and mechanical data

RAY26P-xxxxx1
Sensing range max.
0 ... 1.5 m
(with reflector PL80A)
Light band dimen‐
24 mm x 9 mm (1 m)
sions / distance
approx.
Minimum detectable
≥ 1 mm
object (MDO)
Minimum distance
0 mm
between sensor and
reflector
Supply voltage U
10 ... 30 V DC
B
Current consumption
≤ 25 mA
Output current I
≤ 100 mA
max.
Communication mode
COM2
IO-Link
1.1
Max. response time
≤ 3 ms
Switching frequency
170 Hz
Enclosure rating
IP66, IP67
Protection class
III
Circuit protection
A, B, C, D
Ambient operating tem‐
–40 °C ... +60 °C
perature
1)
RAY26P-xxxxx3: sensing range depends on the selected MDO (selectable via IO-Link):
3 mm = 0 ... 2 m
5 mm = 0 ... 3 m
10 mm = 0 ... 4.5 m
2)
16 VDC to 30 VDC, without load
3)
10 VDC to 16 VDC, without load
4)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
5)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
6)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
7)
Avoid condensation on the front screen of the sensor and on the reflector.
8)
Allowed temperature change after Teach +/- 20 K
8022178.168D | SICK
Subject to change without notice
RAY26P-xxxxx3
0 ... 4.5 m
55 mm x 9 mm (1m)
≥ 3 mm, 5 mm or 10
mm
1)
, < 50 mA
2)
3)
4)
5)
6)
7)8)
TECHNICAL DATA
RAY26P-xxxxx5
RAY26P-xxxxx9
0 ... 3 m
0 ... 4.5 m
≥ 5 mm
≥ 10 mm
11
15

Publicidad