Figure 9 shows the pattern for the maximum range in the
optimum position.
Selectable options
Figure 10 shows the DIL switch position.
Pulse count
Pulse count is the number of times the detector must detect a
presence before signalling an alarm.
Switch 2 ON = Pulse count 2
Switch 2 OFF = Pulse count 1 (most sensitive)
Detection LED
Switch 1 ON = LED Enabled
Switch 1 OFF = LED Disabled
Walk test & settling time
Allow 3 minutes for the electronics to settle when power is
applied before commencing the walk test.
To enable the LED to carry out a walk test turn Switch 1 to ON.
The detection LED lights each time the Mini PIR detects your
presence.
After walk test is complete turn Switch 1 to OFF if the LED
indication is not required.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Pan and tilt the lens module over the
field of view to obtain the correct coverage area.
Specifications
Coverage
14° to 70° detection angle,
15 m x 13 m coverage max.
Adjustment
90° pan, 45° tilt
Fresnel lens
20 zones for each detection element, which
can be masked with the curtain sliders
Customised optics
Double silicon shielded quad element
eliminates 50,000 Lux of white light
LED
Red: detector alarm
Outputs
Silent, solid state, magnetically immune
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds
Power input
9 to 15 VDC
Current
5.5 mA (12 V nominal)
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with non-volatile
memory
Walk test
Output test mode with LED indication. Option
to disable LED
4 / 21
Operating temperature
−30° to +65°C
Housing
High impact ABS plastic with HDPE cover,
UV stabilised
Dimensions W x H x D
70 mm x 120 mm x 95 mm
Weight
221 g Net, 321 g Gross
Mounting height
Variable up to 6 m.
Optimum height 3 m for full range
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
EN
This products meets the requirements of EMC
Testing to the following standards:
EN 50130-4:2011
EN 61000-6-3:2007
This product meets the environmental
requirements of EN50130-5.
Electrical Safety
This product meets the requirements of Low
Voltage Directive (LVD): 2006/95/EC
Harmonised Standards:
EN60950 - 1:2006+A12:2011
EN60950 - 22:2006+A11:2008
Environmental
IP65
class
European Union
2004/108/EC (EMC directive): Hereby, UTC Fire
directives
& Security declares that this device is in
compliance with the essential requirements and
other relevant provisions of Directive
2004/108/EC.
2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support
DE: Installationsanleitung
Lieferumfang
Im Lieferumfang ist Folgendes enthalten:
•
1 x Mini PIR
• REV A • ISS 10DEC13