Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note:
Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See "SW1-6: LEDs" on page 5.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See "SW1-6: LEDs" on
page 5 for more details.
Table 5: LEDs and outputs
Status
Red
Alarm
LED
relay
Start up
Closed
Low voltage
Open
PIR intruder alarm
Closed
Microwave intruder
Closed
alarm
Dual motion
Open
intruder alarm
Latched PIR
Closed
(memory)
Continuously on
Normal blinking (1 Hz)
Specifications
Detector technology:
DD1012
DD1012PI
Range
Viewing angle
PIR optics
Microwave frequency
Max microwave output at 1 m
Memory function
Input power
Peak-to-peak ripple immunity
Detector start-up time
Current consumption
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Alarm time
Operating temperature
Relative humidity
Weight
Dimensions (H x W x D)
IP/IK rating
Pry-off tamper
6 / 36
Fault
To reset
relay
Closed
Automatically after
60 s
Open
Apply correct voltage
Closed
Closed
Closed
Automatically after
3 s
Closed
Switch to the night
mode
Dual
Dual, pet immune
4, 6, 9, 12 m selectable via SW1-1
and SW1-2
78 degrees
9 high-density mirror curtains
5.8 GHz
0.003 μW/cm²
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
60 s
5 to 16 mA (8 mA nom.)
1.8 to 3.0 m (5.90 to 9.84 ft.)
0.2 to 3.0 m/s (8 in./s to 10 ft./s)
80 mA 30 V , Form A
3 s
−10 to +55°C (14 to 130°F)
95% max., noncondensing
120 g
126 × 63 × 50 mm
IP30 IK04
Optional (ST400)
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com.
For customer support, see www.interlogix.com/customer-
support.
DA: Installationsvejledning
Beskrivelse
DD1012(-D) & DD1012PI er kombi detektorer. De omfatter den
patentbeskyttede PIR-spejloptikteknologi med den
patentbeskyttede Range Controlled Radar-teknologi.
DD1012PI er designet til at ignorere en given størrelse og
bygning af kæledyr. Kæledyr op til 18 kg (ca 35 cm høje) giver
normalt ikke problemer ved standardanvendelse, medmindre
de kan bevæge sig over 35 cm fra gulvet i detektorens
synsfelt.
Installationsvejledning
Se figur 1.
Detektoren er beregnet til vægophæng men kan også
monteres i loftet med et monteringsbeslag.
Følg denne vejledning til at fastlægge den bedste placering til
installation af detektoren.
•
Monter detektoren så den forventede bevægelse ved et
indbrud er på tværs af detektionsmønstret (se figur 3).
•
Monter detektoren på en stabil overflade i en højde på
1,8 m — 3,0 m fra gulvet.
•
Monter ikke detektoren på en afstand af 0,5 m fra
metalgenstande eller 1,5 m fra lysstofarmaturer.
•
Placer ikke en genstand foran detektoren, som kan
forhindre en direkte synslinje.
•
Placer detektorerne mindst 6 m fra hinanden og juster
afstanden på enheden, således at man undgår interferens
ved montering af detektorerne rettet mod hinanden.
Detektorteknologien beskytter effektivt mod falske alarmer.
Undgå imidlertid mulige årsager til ustabilitet, f.eks.:
PIR-fare:
•
Direkte sollys på detektoren
•
Varmekilder inden for detektorens synsfelt
P/N 146550999-1 • REV C • ISS 05APR12