Green mode
When SW1-5 is set to Remote on, the radar is switched off
during the day mode (with no WT) to reduce current
consumption. The detector is then operating in PIR only mode.
Note:
The Day/night line must be connected to the control
panel for this mode to work.
Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note:
Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See "SW1-6: LEDs" on page 5.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See "SW1-6: LEDs" on
page 5 for more details.
Table 5: LEDs and outputs
Status
Red
LED
Start up
Low voltage
PIR intruder alarm
Microwave intruder
alarm
Dual motion intruder
alarm
Latched PIR (memory)
Continuously ON
Normal blinking (1 Hz)
Specifications
Detector technology
Range
Viewing angle
PIR optics
Microwave frequency
Max microwave output at 1 m
Memory function
Input power
Peak-to-peak ripple immunity
Detector start-up time
Current consumption
Mounting height
INCERT installations
Target speed range
Alarm (NC) / Tamper relay
characteristic
6 / 36
Alarm
Fault
To reset
relay
relay
Closed
Closed
Automatically after
60 s
Open
Open
Apply correct
voltage
Closed
Closed
Closed
Closed
Open
Closed
Automatically after
3 s
Closed
Closed
Switch to the night
mode
Dual
10, 12, 14, 16 m selectable via
SW1-1 and SW1-2
78 degrees
9 high-density mirror curtains
5.8 GHz
0.003 μW/cm²
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
60 s
5 to 16 mA (8 mA nom.)
1.8 to 3.0 m (5.9 to 9.8 ft.)
2.0 to 3.0 m (6.6 to 9.8 ft.)
0.2 to 3.0 m/s (8 in./s to 10 ft./s)
80 mA 30 V , Form A
Alarm time
Operating temperature
Relative humidity
Weight
Dimensions (H x W x D)
IP/IK rating
Pry-off tamper

Regulatory information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com.
For customer support, see www.interlogix.com/customer-
support.
DA: Installationsvejledning
Beskrivelse
DDV1016 er en kombidetektor.
Den omfatter den patentbeskyttede PIR-spejloptikteknologi
med den patentbeskyttede Range Controlled Radar-teknologi.

Installationsvejledning

Se figur 1.
Detektoren er beregnet til vægophæng men kan også
monteres i loftet med et monteringsbeslag.
Følg denne vejledning til at fastlægge den bedste placering til
installation af detektoren.
Monter detektoren så den forventede bevægelse ved et
indbrud er på tværs af detektionsmønstret (se figur 3).
Monter detektoren på en stabil overflade i en højde på
1,8 m — 3,0 m fra gulvet.
Monter ikke detektoren på en afstand af 0,5 m fra
metalgenstande eller 1,5 m fra lysstofarmaturer.
Placer ikke en genstand foran detektoren, som kan
forhindre en direkte synslinje.
Placer detektorerne mindst 6 m fra hinanden og juster
afstanden på enheden således at man undgår interferens
ved montering af detektorerne rettet mod hinanden.
P/N 146552999-1 (ML) • REV D • ISS 23MAY12
3 s
−10 to +55°C (14 to 130°F)
95% max., noncondensing
120 g
126 × 63 × 50 mm
IP30 IK04
Optional (ST400)