Regulatory Information - Interlogix DDI602AM Hoja De Instalación

Ocultar thumbs Ver también para DDI602AM:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Fault/A-M relay AND the Alarm relay will operate. In this latter
condition the small red LED will illuminate.
Self-calibration takes place every evening during decreasing
ambient light and every morning during increasing light. This
compensates for natural build up of dirt on the front cover;
which could otherwise cause a false Fault/Anti-Mask detection.
After a Fault/Anti-Mask alarm and the mask is removed, the
Fault/Anti-Mask alarm contact will close. Then after a further
20 seconds the next detection will initiate a self-calibration.
Voltage Check
The unit self-tests the supply voltage and if out of specification
the Fault/Anti-Mask relay will open until the supply voltage is
within specification.
Remote LED Operation
The LEDs will get enabled when a negative voltage is applied
to the LED terminal.
Remote Self-Test
A self-test routine will commence when a negative voltage is
applied to the TEST terminal. The Anti-Mask detector
constantly self-checks and will operate the Fault/A-M relay if an
internal fault condition is detected.
Accessories
UTC Fire & Security can provide a handheld walk tester DI601-
WT to aid installations.
Specifications
Detection range
Programmable: 10 m, 20 m or 30 m
Coverage
10 to 70° detection angle, 30 x 24 m
coverage max.
Adjustment
−45° to +45° pan, tilt +45°
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
Customized optics
Double silicon shielded quad element
eliminates 50,000 lux of white light
LEDs
Top PCB
Red: Programming LED
Sensor PCB
Blue: Detector alarm
Red(small): Anti-mask alarm
Infrared: Walk tester communication
Red: PIR active
Green: Microwave active
Microwave module
operating frequency
(country specific)
DDI602AM-F1
10.525 GHz
DDI602AM-F2
10.587 GHz
DDI602AM-F3
9.9 GHz
Outputs
Silent, solid state, magnetically immune.
NO
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
P/N 146655999-1 • REV A • ISS 30JUN14
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
Fault/Mask
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor
Power input
10 to 15 VDC
Current
21 mA (12 V nominal)
Standby 41 mA MAX
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with nonvolatile
memory
Walk test
Output test mode with LED indication.
Option to disable LEDs.
Operating temperature
−30 to +65°C
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
Dimensions, W x H x D
125 x 175 x 130 mm
Weight
365 g net, 551 g gross
Mounting height
Variable up to 6 m
Optimum height 3 m for full range

Regulatory information

Manufacturer
Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 280923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
EN 50130
EN50130-5
EN 50131
EN50131-2-4, Grade 3, Class IV
Certified by Telefication B.V.
Note:
EN50131-2-4 compliant only when mounted
at 1.5 and 3 m
Environmental
IP65
class
This product meets the environmental requirements
of EN50130-5.
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of one or more of the
Directives 1999/5/EC, 2014/30/EU and 2014/35/EU.
For more information see:
www.utcfireandsecurity.com or www.interlogix.com.
2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info.
Usage
Only use the listed models in the following
restrictions
countries:
DDI602-F1
Albania, Argentina, Australia, Belgium, Brazil,
(10.525 GHz)
Denmark, Holland, Hungary, Iceland, Indonesia,
Latvia, Lithuania, Malta, Norway, Portugal, Russia,
South Africa, Spain, Sweden, Taiwan, Ukraine,
USA.
7 / 47

Publicidad

Tabla de contenido
loading

Tabla de contenido