Section 7: Control Panel/Start–Up/Testing

Preparing for Start-Up

DANGER
Automatic start-up. Disconnect normal power source
and render unit inoperable before working on unit.
Failure to do so will result in death or serious injury.
Before performing any maintenance on the generator, set
to OFF, remove fuses, and disconnect battery cables to
prevent accidental start up. Disconnect the cable from
the battery post indicated by a NEGATIVE, NEG or (–)
first, then remove the POSITIVE, POS or (+) cable.
When reconnecting the cables, connect the POSITIVE
cable first, the NEGATIVE cable last.

Control Panel Interface

The Control Panel Interface is located under the lid of the
enclosure. Before attempting to lift the lid of the
enclosure, verify that both left and right side locks are
unlocked.
When closing the unit, verify that both left and right side
locks are securely locked.
NOTE: All appropriate panels must be in place during
any operation of the generator. This includes operation
by
a
servicing
technician
troubleshooting procedures.
Figure 7-1. Generator Control Panel Location
With the control pad set to AUTO, the engine may crank
and start at any time without warning. To prevent possible
injury that might occur during sudden starts, always set
the control pad to OFF and remove the 7.5 amp fuse
before working on or around the generator or the
electrical loads that are to be powered by the generator.
For added security, place a DO NOT OPERATE tag or
placard at the control pad and the electrical loads that are
to be powered by the generator.
Never run the generator with any access panel removed.
Installation Guidelines for 60 Hz EcoGen™ Generator

Using the AUTO/MANUAL/OFF Buttons

(000236)
while
conducting
001428
Generator Set–Up
When battery power is applied to the generator during
the installation process, the controller will light up.
However, the generator still needs to be activated before
it will automatically run in the event of a power outage.
Button
Description of Operation
Auto
Press to activate fully automatic operation. Green
LED illuminates to confirm that system is in AUTO
mode. Transfer to standby power occurs if 2–wire
start signal is enabled.
Off
Press to shut down engine, if running. Red LED
illuminates to confirm that system is in OFF mode.
Manual
Press to crank and start engine. Blue LED
illuminates to confirm that system is in MANUAL
mode.
A
B
C
D
Figure 7-2. Generator Control Panel
A.
LCD Screen
B.
Auto
C.
Manual
D.
Off
E.
Escape
F.
Down Arrow
G.
Enter
H.
Up Arrow