Before Startup - Kärcher Winner 1100 M Manual De Instrucciones

Ocultar thumbs Ver también para Winner 1100 M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Overflow valve with pressure switch
The overflow valve prevents the permissible
working pressure from being exceeded.
If the lever on the trigger gun is released the
pressure switch turns off the pump, the high-
pressure jet is stopped. If the lever is pulled the
pump is turned on again.
Prerequisites for the appliance's
stability
Caution
Create stability for the appliance prior to all work
on or with the appliance to prevent accidents or
damage.
The stability of the appliance is warranted
when it is placed onto an even surface.
Operation
Description of the Appliance
The scope of delivery of your appliance is illus-
trated on the packaging. Check the contents of
the appliance for completeness when unpack-
ing.
In the event of missing accessories or any trans-
port damage, please contact your dealer.
Illustrations on Page 2
1
High pressure connection
2
Detergent suction hose (with filter)
3
Appliance switch "0/OFF"/ „I/ON"
4
Storage for high-pressure hose
5
Carrying handle
6
Transport handle, detachable
7
Storage for spray lance
8
Storage for trigger gun
9
Mains cable with mains plug
10 Connection for water supply with filter
11 Bearing wheel
12 Coupling element for water connection
13 Trigger gun
14 High pressure hose
15 Lock trigger gun
16 Clamp for high pressure hose
17 Spray lance with Dirtblaster
18 Spray lance with high pressure nozzle
According to the applicable regulations,
the appliance must never be used on the
drinking water net without a system sep-
arator. Use a suitable system separator as per
EN 12729 type BA. Water flowing through a sys-
tem separator is considered non-drinkable.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/technical
data.
Use a fibre-reinforced water hose (not in-
cluded) with a standard coupling. (Minimum
diameter 1/2 inch (13 mm), minimum length
7.5 m).
Screw the coupling element (supplied) to the
water connection on the appliance.
Push the water supply hose onto the cou-
pling unit, then connect it to the water supply.
Mount loose parts delivered with appliance prior
to start-up.
Illustrations on Page 2
Illustration
Insert the transport handle.
Illustration
Insert the transport wheels and lock them.
Illustration
Pull out the clamp for the high-pressure hose
from the trigger gun (e.g. a small screwdriv-
er).
Illustration
Connect high pressure hose to trigger gun.
Push the clamp in until it locks. Check the se-
cure connection by pulling on the high-pres-
sure hose.
Caution
Dry runs lasting longer than two minutes lead to
damages to the high pressure pump. If the appli-
ance does not build up pressure within two min-
utes, switch it off and proceed as instructed in
the Chapter "Troubleshooting".
In case of impurities in the supply water, a 3/4"
fine water filter must be used.
Connect the high pressure hose to the high
pressure connection of the appliance.
Push the spray lance into the trigger gun and
fasten it by turning it through 90°.
– 5
EN
Water supply

Before Startup

Start up
11

Publicidad

Tabla de contenido
loading

Tabla de contenido