WARNING!
Only use original nozzles!
It is forbidden to make any alterations!
Exhaust removal
In accordance with regulations, gas devices must be installed in a place adapted for
ventilation of exhaust.
There are two ways of connecting a gas device to such an exhaust removal system.
- 60 -
If the device is to be connected to gas that is
not listed in the power rating table, change the
burner nozzle in the following way:
Unscrew the nozzle and replace it with the
appropriate nozzle according to the gas
type table.
Use a sealing ring (fig. at the left/B).
Nozzles are marked in 1/100 mm.
After changing the nozzle, check the gas
pressure again.
• Connecting to a natural outlet, such as a
naturally-aspirated pipe system, which must
remove exhaust gases directly outside or to a
furnace. This can be accomplished with a metal
sheet or wind shield, available separately.
Exhaust removal must not be impeded by
reductions or long exhaust pipes (max. 3 m).
• Installation of a system with forced exhaust
removal, such as a fume hood with mechanical
exhaust removal.
Gas delivery must be directly regulated by the
exhaust system, and interrupted when the
exhaust removal system functions at lower
efficiencies than the minimum recommended
values.