Connecting HART: typical PLC/mA configuration
power
R = 250 
supply
SITRANS
LR200
1)

Wiring setups for hazardous area installations

Note: ATEX certificates and connection drawings listed below can be downloaded from the
product page of our website at: www.siemens.com/LR200.
There are six wiring options for hazardous area installations. In all cases, check the device
nameplate and process device tag to verify the approval rating.

1. Intrinsically Safe wiring

Device nameplate (ATEX/IECEX/INMETRO/C-TICK)
SITRANS LR200
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40°C to 80°C
Power Rating: 24 V
Nom., 30 V
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
The ATEX certificate can be downloaded from the product
page of our website at: www.siemens.com/LR200. Go to Support > Approvals / Certificates.
The IECEx certificate listed on the nameplate can be viewed on the IECEx website. Go to:
http://iecex.iec.ch and click on Ex Equipment Certificates of Conformity then enter the
certificate number IECEx SIR 13.0006X.
1)
Curve 1: General Purpose, Intrinsically Safe, Non-Sparking, Non-incendive
See
Flameproof, Increased Safety, Explosion-proof
A5E31993614
active PLC
HART
modem
HART
communicator
5.8 GHz
HART
KCC-REM-S49
SITRANSLR
Max., 4 - 20 mA
SITRANS LR200 (HART) – QUICK START MANUAL
Notes:
• Depending on the system design,
the power supply may be separate
from the PLC, or integral to it.
• HART resistance (cable resistance
plus 250 Ohm [resistor]) must be
limited according to the allowable
operating area
• Do not connect more than one
HART programming device at a
time.
U i = 30 V
II 1 G
I i = 120 mA
Ex ia IIC T4 Ga
P i = 0.8 W
SIRA 06ATEX2378X
C i = 15 nF
IECEx SIR 13.0006X
L i = 0.1 mH
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA - VEJA INSTRUÇÕES
on page 22.
1)
.
OCP 0017
Ex ia IIC T4 Ga
DNV 12.0143 X
Curve 2:
on page 22 or
Page EN-9