BURNER OUTPUT CALCULATION
To calculate the burner output in kW follow khe procedure below:
Check on the meter the gas flow in litres and the reading time in seconds.
Calculate using the formula :
e x f = kW
sec
AIR ADJUSTEMENT
To adjust the inlet air flow:
- Loosen screw A.
- Turn air damper B through
lever C, till to obtain the pro-
per air flow, determined
through a combustion analy-
sis.
- Tighten screw A.
REMOVING THE BLAST TUBE
SEZIONE B-
B
A
C
B

POSITION OF ELECTRODES

Ignition electrode
A
B
A
11
420010268002 Blu 700.1 P Low Nox
e
sec
G20 = 34,02
G25 = 29,25
F
G30 = 116
G31 = 88
SETTING THE FIRING HEAD
The adjustment of the position of the firing head is
made to obtain the best combustion performance.
When used at the minimum power output the
firing head is move back, whilst is forwarded at the
maximum output. Execution : -loosen the locking
screw of adjusting device A; - move the adjusting
device until the desired position is reached; - tighten
the locking screw.
Ionization probe
B
SE
= litres of gas
= time in seconds
A
ZION
E
A A
-