BURNER OUTPUT CALCULATION
To calculate the burner output in kW follow khe procedure below:
Check on the meter the gas flow in litres and the reading time in seconds.
Calculate using the formula :
e x f = kW
sec
AIR ADJUSTEMENT
To adjust the inlet air flow:
- Loosen screw A.
- Turn air damper B through
lever C, till to obtain the proper
air flow, determined through a
combustion analysis.
- Tighten screw A.
REMOVING THE BLAST TUBE
SEZIONE B-
B
A
C
B

POSITION OF ELECTRODES

Ignition electrode
A
B
A
9
420010268000 Blu 500.1 P ÷ 700.1 P Low Nox
e
sec
G20 = 34,02
G25 = 29,25
F
G30 = 116
G31 = 88
SETTING THE FIRING HEAD
The adjustment of the position of the firing
head is made to obtain the best combustion
performance. When used at the minimum
power output the firing head is move back,
whilst is forwarded at the maximum output.
Execution : -loosen the locking screw of adju-
sting device A; - move the adjusting device until
the desired position is reached; - tighten the
locking screw.
Ionization probe
B
SE
= litres of gas
= time in seconds
A
ZION
E
A A
-
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Blu 700.1 p

Tabla de contenido