Table of contents
7.0 Servicing ........................................................32
Figures ...................................................................74
All manuals and user guides at all-guides.com
1.0 Relationship to the
authorities
Installation of a stove must be in accordance with the particular
country's laws and regulations and your dealer may provide
assistance in ensuring that your installation is safe and legal.
Prior to using the product the installation must be approved by
a qualified person.
Instructions for mounting, installation and use are enclosed with
the product. The installation may only be used once it has been
inspected and approved.
A product data plate in heat resistant material can be found
on the heat shield under the insert. It contains the following
information: manufacturer, address, product name, catalogue
number, production number and output.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max.:
Heat output:
Flue outlet:
Flue pipe (for product with
side-hinged door):
Flue pipe (for product with
guillotine door):
Weight (for product with
side-hinged door):
Weight (for product with
guillotine door):
Product dimensions, fire
barrier measurements etc.:
Technical data according to EN 13229
Nominal heat output:
Smoke gas mass flow:
Recommended chimney draught:10 Pa
Effiency:
CO emission (13% O
Flue gas temperature:
Operating mode:
eNglish
Cast iron and steel
Black paint
Wood
60 cm
Max 20.0 kW
Top
Min. Ø200 mm/ 314 cm
Ø250 mm/ 491 cm
Approx. 230 kg
Approx. 272 kg
See fig. 1 and 2
14 kW
16,6 g/s
73% @ 13,9 kW
):
0,12%
2
281
C
0
Continuous
2
2
25