6.4
Runtime meter
6.5
Main nozzle set (nozzle + spark plug)
6.6
Weight carrier
EN
122
The runtime meter counts the operating hours and records the engine speed (LCD display).
The operating hours can only be read if the engine is switched off. While the engine is
running, the engine speed is shown. The runtime meter cannot be reset. It has its own
battery welded to the housing.
Running engines at high elevations will result in a loss of performance. This is caused by
overlubrication in some operating states as a result of the change in the mixing ratio due to
the lower air weight.
This problem can be prevented by mounting the main nozzle set.
The weights on the weight carrier are used for balancing the machine optimally and
increase the traction of the wheels.
Heavy attachment units increase the lifting force on the handlebar. Stacked weights on the
weight carrier can reduce the lifting force.
In case of 3 weights (1), they are directly mounted to the weight carrier (2) and clamped with
the star grip (3). In this case, the retaining spring (4) is not required and can be stored in the
bottommost row of slots.
When using fewer than 3 weights (1), the retaining spring (4) serves as support of the
weights, the weights being in the topmost position. The weights are clamped with the star
grip (3).
Maximum 3 stacked weights each of 8.5 kg are permitted on the weight carrier.
Note
Machine no. from CI 1001