Weee; Spare Parts; Electrical Schematic - Lincoln Electric TOMAHAWK 1025 Manual De Instrucciones

Ocultar thumbs Ver también para TOMAHAWK 1025:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Duty Cycle
(Based on a 10 min. period)
TH1025
TH1538
Cutting Current Range
TH1025
20 - 60A
TH1538
20 - 100A
Required Flow Rate
TH1025
TH1538
Fuse (delayed) or Circuit Breaker ("D" characteristic) Size
TH1025
TH1538
Height
TH1025
389mm
TH1538
455mm
Operating Temperature
-10°C to +40°C

WEEE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)
and its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will protect the environment and human health!

Spare Parts

Part List reading instructions
Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service
Department for any code number not listed.
Use the illustration of assembly page and the table below to determine where the part is located for your particular
code machine.
Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate
a change in this printing).
First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that
contains a picture-descriptive part number cross-reference.

Electrical Schematic

Refer to the "Spare Part" manual supplied with the machine.
English
RATED OUTPUT AT 40°C
100%
60%
40%
100%
60%
40%
Maximum Open Circuit Voltage
TH1025
TH1538
COMPRESSED AIR or GAS
130 ±20% l/min @ 5.5bar
180 ±20% l/min @ 5.5bar
RECOMMENDED INPUT CABLE AND FUSE SIZES
20A
32A
PHYSICAL DIMENSIONS
Width
TH1025
247mm
TH1538
301mm
Output Current
40A
50A
60A
60A
85A
100A
OUTPUT RANGE
320VDC
320VDC
TH1025
TH1538
Length
TH1025
TH1538
7
Output Voltage
96VDC
100VDC
104VDC
104VDC
114VDC
120VDC
Pilot Arc Current
TH1025
TH1538
Required Inlet Pressure
6.0bar ÷ 7.5bar
Input Power Cable
2
4 x 2.5mm
2
4 x 4mm
Weight
510mm
TH1025
640mm
TH1538
Storage Temperature
-25°C to +55°C
20A
20A
22kg
34kg
07/06
12/05
English

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tomahawk 1538

Tabla de contenido