Technical Data - Aventics AF2 Instrucciones De Servicio

Sensor de medición de caudal
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
AVENTICS | AF2 | R412026496–BAL–001–AA | English

13 Technical Data

Technical Data
Measuring principle
Medium
Standard measurement range
Extended measurement range
Display range
4 mA correspond to
20 mA correspond to
Process temperature
Process pressure
Communication interface
Display
1)
Sensor element precision
Reproducibility
Response time (T90)
Temperature measurement
precision
Temperature reproducibility
Pressure measurement:
Measurement precision
Non-linearity
Reproducibility
2)
Supply voltage U
V
Power consumption
Initialization time
Protection class
Connection type
4)
Output signal
4)
Output load
4)
Lower signal level
4)
Upper signal level
4)
Digital output
4)
Signal voltage HIGH
4)
Signal voltage LOW
4)
Inductive load
4)
Capacitive load
MTTF
Calorimetric (flow)
Pt1200 (temperature)
Piezo-resistive (pressure)
Pressure (air quality acc. to ISO 8573-1:2010 [3:4:4])
Helium, argon, nitrogen, carbon dioxide
AS2: 5 ... 1060 l/min
AS3: 8 ... 1630 l/min
AS5: 22 ... 4326 l/min
AS2: 1060 ... 1590 l/min
AS3: 1630 ... 2445 l/min
AS5: 4326 ... 6490 l/min
AS2: 0 ... 3180 l/min
AS3: 0 ... 4890 l/min
AS5: 0 ... 12980 l/min
AS2: 0 l/min
AS3: 0 l/min
AS5: 0 l/min
AS2: 3200 l/min
AS3: 5000 l/min
AS5: 13000 l/min
-20 to +60°C
0 to 16 bar
IO-Link 1.1 Com3 (only for IO-Link version)
Ethernet (only for Ethernet version) - OPC
UA, MQTT and WebServer
128 x 128 pixels, electronically rotatable OLED display
(90° rotations) and 4 buttons
±3% of the measured value +0.3% of the standard
measurement range end value
±8% of the measured value +1% of the extended
measurement range end value
±1.5% of the measured value
< 0.3 s
±2°C
±0.5°C
≤ ±1.5% of the measurement range
(in the range of 10 ... 30°C)
≤ ±0.5% of the measurement range
≤ ±0.2% of the measurement range
17 ... 30 VDC
< 12 W (@ 24 VDC without output load)
≤ 10 s
III
M12x1 round plug, 5-pin A-coded (IO-Link version);
M12x1 round plug, 8-pin X-coded (Ethernet version)
1 x analog output 4 ... 20 mA, or 1 x digital switch output /
pulse, frequency output configurable, 1 x analog output
4 ... 20 mA or 1 x digital switch output (configurable)
4 .. 20 mA, 500 ohms, if Uv > 15 V
3.5 ... 3.8 mA
20.5 ... 21.5 mA
≤ 100 mA per output
> Uv - 2 V
≤ 2 V
1 H
100 nF (2.5 nF for IO-Link)
> 50 years
Process connection
Parts that are in contact with the
media
Housing material
Protection class
Weight
Ambient temperature (operation)?
Ambient temperature (storage)
Max. permissible relative humidity ≤ 90% RH, non-condensing
1) Reference conditions according to DIN 1343: Atmospheric pressure 1.01325 bar abs., compressed air
temperature 0°C
2) All connections are protected against reverse polarity and are overcurrent-proof. Q1, Q2, and Qa are short-
circuit-resistant.
3) Configuration of the digital output: PNP/NPN/push-pull.
4) Only IO-Link-version
Further technical data can be found in our online catalog at
www.aventics.com/pneumatics-catalog
3)
G3/8", G1/2", G1" (according to DIN ISO 228-1)
Stainless steel 1.4305, PA6, Viton®, aluminum
PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel
1.4301
IP65 and IP67 (IP67 according to EN 60529)
G3/8" 1300 g (850 g*)
G1/2" 2050 g (1250 g*)
G1" 2970 g (2300 g*)
*Without mounting
-20 ... +60°C
-40 ... +85°C
20

Publicidad

Tabla de contenido
loading

Tabla de contenido