Faults
Use only original spare and accessory parts.
Fault
No pressure builds up in
the device
Liquid flows out of the
pump.
Safety valves blows off
too early.
Pressure gage is not
indicating any tank pres-
sure.
Contact address for additional information → see title page.
Warranty
We guarantee that from the time it is first purchased for a period of the legally valid requi-
red warranty period (maximum 3 years) this device will not exhibit any material or proces-
sing errors. If defects are discovered during the warranty period, MESTO or the distributor
in your country will repair the device without charging for the labor or material or (at the
discretion of MESTO) replace the device itself or its defective parts.
If such defects are discovered, please contact us immediately. We require the invoice or
cash register receipt for purchase of the device.
The warranty does not include wearing parts (seals, O-rings, diaphragm, etc.) or defects,
which have occurred due to improper use or unforeseeable circumstances.

Declaration of Conformity

Products which belong to the 3585 and 3615 series satisfy the requirements of the Pressu-
re Equipment Directive 2014/68/EU and carry the CE mark.
The data and illustrations in these instructions for use are for orientation only and not
binding in any way. The manufacturer reserves the right to make changes or improvements
to the products if these are considered appropriate without having to notify customers
owning a similar model about this fact.
0919
Cause
The pump is not screwed on
tightly.
O-ring [19] on the pump is
faulty.
Diaphragm [20] is defective.
Valve disk [21] dirty of defec-
tive.
Safety valve [10] is defective. Replace safety valve. (Fig. 17)
Pressure gage [14] defective. Sever attachments (at top, at
Original operating instructions
17
Remedy
Screw the pump on tightly
Replace the O-ring. (Fig. 16)
Replace the diaphragm. (Fig. 16)
Clean or replace the valve disk.
(Fig. 15)
bottom, on right) [22]. (Fig. 18)
Open panel [23], unscrew pres-
sure gage [14] with wrench and
replace. (Fig. 18)
Insert fixing knob [24], push to
right and insert panel [23].
(Fig. 19)