2.4.3
Wiring diagram
3
OPERATION AND MANTEINANCE
WARNING: Protect the water outlet from wind and do not operate in strong wind. If
the unit is installed in a windy area, water outlet could be often displaced.
3.1
OPERATION
The operation of the unit will depend on the control system installed, which is not
supplied with this unit.
DANGER: Risk of injuries. Maximum jet height must not exceed 4m if the units are
installed on a dry fountain.
WARNING: Risk of unit damage. The maximum working water pressure is 4 bar.
WARNING: Risk of unit damage. On/off switching of the unit is commanded by a
relay with activation frequencies exceeding 0,5seconds.
3.2
MAINTENANCE
For the maintenance of the components made of stainless steel, see the manual
attached.
It is highly recommendable to activate the device at least once a month to check
the proper electrovalve operation.
Check device's inlet filter status weekly.
24