Calibration Procedures - TOUGHBUILT TB-H2-LL-30-L2 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Should the laser beam keep fluctuating, it is an indication that the tool is tilted
beyond its self-leveling limits. It may also be an indication of low battery power.
PLEASE NOTE: Green Laser expands as the distance between the tool and the
target increases. Therefore, always take measurements in the center of the beam.
Before and during work intervals, wipe the laser lens with a lint-free cloth. Dirt on
the reflector surface may cause laser deflection and cause false readings.
IMPORTANT REMINDER! At the beginning of each job, mark an index
point. All future measurements will be based on that index point.

CALIBRATION PROCEDURES:

First step to verify LEVEL (Horizontal) laser beam calibration
To verify the calibration, use a large room (at least 12 x 16 ft.).
1.
At the long end of the room, place the Laser Level one foot from side wall
"A" and 8 feet from the facing wall. Slide the Pendulum Switch
UNLOCK position. Allow a few seconds for the pendulum to stabilize.
2.
Cut four strips of painter's blue tape or masking tape each piece about
two-inches long. Adhere the tape strips onto the walls over the laser
beam at locations A, B, C and D.
3.
Using a ruler, scribe a line at the center of the laser beam on each piece of tape.
Scribe lines underneath the laser beam on the remaining three strips of tape.
4.
Slide the Pendulum Switch
across the room and position it one foot from the wall at position "D"
16
2
to the LOCK position. Relocate the tool
2
to the

Publicidad

Capítulos

Tabla de contenido
loading