Standard Operation
Wireless Monitor Status LED's
• The wireless monitor receives data from the
generator every 10 minutes and displays the
generator status through 3 LED's.
• Pressing the SYSTEM UPDATE button will provide
current generator status by flashing the status
LED's. When pressed, all 3 LEDs will flash until the
generator status is received.
NOTICE Generator control panel must be in AUTO mode
or no communication with monitor will occur.
• In order to conserve power and to extend battery
life, the LED's are not lit continuously; instead they
are briefly flashed as indicated below.
NOTICE During the weekly exercise cycle, the generator
will run for 20 minutes, but it will not supply power to the
home. During the exercise cycle, the monitor will continue
blinking the GENERATOR READY green LED.
• GENERATOR READY - When active, the green LED
will flash once every 7 seconds. The green LED
indicates that the generator is in AUTO mode and
that it is ready to run in the event of a loss of utility
power.
• GENERATOR POWER - When active, the green
LED will flash every 7 seconds. The green LED
indicates that the generator is supplying power.
• SERVICE NEEDED - When active, the red LED will
flash in a sequence that corresponds to the service
code. For example, when Low Frequency scrolls
across the control board, the red LED will flash 5
times with a 3 second pause between series of
blinks until it is reset or the condition is corrected.
Contact the nearest authorized service dealer if the
problem can not be fixed.
NOTICE Service conditions will only be displayed on the
basic monitor when the control board is placed in AUTO
mode.
22
:
Other:
LED Lighting Codes
• No status LEDs illuminated - Generator in OFF
mode or check and replace batteries.
Wireless communication lost issues can typically be
resolved by moving the wireless monitor closer,
within the home, to the standby generator. See
Optional Router Accessory Kit
• Batteries Inserted - the shield LED will light for 5
seconds.
• Linking Error or Not Linked - Each LED will light then
turn off in one direction, then the other direction until
a successful link is completed.
• During the weekly exercise cycle, the generator will
run for 20 minutes, but it will not supply power to the
home. During the exercise cycle, the monitor will
continue blinking the green shield LED.
Service Code Descriptions - name and number of
flashes are listed on the back side of the wireless
monitor.
None of the service needed codes are cleared at
the wireless monitor. All alerts must be cleared at
the generator control panel.
XXXXX
XXXXX
XXXXX