Electronic Governor System - Briggs & Stratton 040517 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electronic Governor System

The engine electronic governor system allows for improved
control and increased generator performance compared
to mechanically governed systems. The result is smooth
steady-state operation without the "hunting" common to
many mechanical governors. The system also reduces
speed variations under engine loading and unloading and
significantly reduces frequency fluctuation experienced
when the engine is under higher loads.
The electronic governor system is composed of a stepper
A
B
motor
, stepper motor throttle control linkages
.
The control board contains a digital controller that
processes engine speed information and sends
appropriate commands to the stepper motor to control the
position of the engine throttle.
B
Since the electronic governing system controls the engine
throttle demand based upon generator load, the following
service codes and/or conditions may be related to an
A
electronic governing system issue:
• Engine Does Not Start
• Over Speed
• Under Frequency
• Unstable No Load Engine Control
While trouble shooting any of these conditions, a
verification of the electronic governor system can be
initiated through the control panel – advanced menu
options – Electronic Governor Check.
Electronic Governing Check
The generator has an electronic governing check feature
that will turn on the stepper motor and move the throttle
linkage clockwise and counterclockwise within the throttle
limits. The test will rotate the stepper motor and move the
throttle arm between the wide open throttle and dead idle
limits 4 times with a 2 second delay between each throttle
sweep. This will allow visual verification that the stepper
motor is functioning properly and the control linkages are
connected. The engine will not attempt to start during this
test. If the stepper motor does not move, or if a linkage
binds,then service may be required.
NOTICE If stepper motor does not move, please make
sure the stepper motor connector is attached.