PROGRAMMING PARAMETERS
Meaning
Open input
Close input
Level I
Level II
Effect after pressing the encoder (A)
parameters
parameters
No command
0
Step-by-step
1
3
Open
Close
4
High-priority Step-by-Step: it moves the automation even if it is locked by a
6
lock command
Opens and locks the automation
7
Closes and locks the automation
8
Courtesy light timer: causes the courtesy light to switch on, which then
1 1
switches off once the courtesy light time has elapsed
Courtesy light on/off: activates or deactivates the courtesy light, which then
1 2
switches off once the courtesy light time has elapsed
I n 2
Photo
1 6
Unlocks and opens the automation
1 9
Unlocks and closes the automation
2 0
Activates opening from Bluebus photocells
2 1
Deactivates opening from Bluebus photocells
2 2
Master barrier Step-by-Step
2 5
Master and slave barrier open
2 6
Master and slave barrier close
2 7
Slave barrier Step-by-Step
2 8
Slave barrier open
2 9
Slave barrier close
3 0
No command
0
Step-by-step
1
Open
3
4
Close
High-priority Step-by-Step: it moves the automation even if it is locked by a
6
lock command
Opens and locks the automation
7
Closes and locks the automation
8
Courtesy light timer: causes the courtesy light to switch on, which then
1 1
switches off once the courtesy light time has elapsed
Courtesy light on/off: activates or deactivates the courtesy light, which then
1 2
switches off once the courtesy light time has elapsed
I n 3
Photo
1 6
Unlock and Open
1 9
Unlock and Close
2 0
Activates opening from Bluebus photocells
2 1
Deactivates opening from Bluebus photocells
2 2
Master and slave barrier Step-by-Step
2 5
Master and slave barrier open
2 6
Master and slave barrier close
2 7
Slave barrier Step-by-Step
2 8
Slave barrier open
2 9
Slave barrier close
3 0
ENGLISH – 73