Connecting An Sm-Type Radio Receiver - Nice M-BAR Serie Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 149

9.4 CONNECTING AN SM-TYPE RADIO RECEIVER

The control unit has a slot for mounting radio receivers with SM
connector (optional accessories) belonging to the SMXI, OXI,
etc. families, which can be used to remotely control the control
unit through transmitters that intervene on the unit's inputs.
f
Before installing a receiver, disconnect the power
supply to the control unit.
To install a receiver ("Figure 49"):
insert the receiver (A) in the appropriate slot (B) on the
1.
control unit's electronic board.
49
A
The association between the radio receiver output and the
command executed by the motor is shown in "Table 18":
SMXI / SMXIS OR OXI / OXIFM / OXIT / OXITFM IN MODE 1 OR MODE
2
Receiver output
Command
"Step-by-Step"
Output No. 1
"Timer-controlled switching on of the
Output No. 2
courtesy light"
"Open"
Output No. 3
"Close"
Output No. 4
If the OXI radio receiver used in "EXTENDED MODE" is installed,
it may send the commands shown in "Table 19".
86 – ENGLISH
B
Table 18
OXI / OXIFM /OXIT / OXITFM IN MODE 2 EXTENDED
No.
Command
1
Step-by-Step
Timer-controlled
2
switching on of
the courtesy light
3
Open
4
Close
5
Stop
Condominium
6
Step-by-Step
High priority Step-
7
by-Step
8
Unlock and Open
9
Unlock and Close
Opens and locks
10
the automation
Closes and locks
11
the automation
12
Lock automation
Release
13
automation
MASTER barrier
14
Step-by-Step
SLAVE barrier
15
Step-by-Step
l
For further information, consult the speciic manual
of the receiver.
Description
"SbS" (Step-by-Step) command
"Timer-controlled switching on of the
courtesy light" command
"Open" command
"Close" command
Stops the manoeuvre
Command in condominium mode
Commands also with the automation
locked or the commands enabled
Unlocks the locked automation and
carries out an opening manoeuvre
Unlocks the locked automation and
carries out a closing manoeuvre
Triggers an opening manoeuvre
and, once this terminates, locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers a closing manoeuvre and,
once this terminates, locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers the stoppage of the
manoeuvre and locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers unlocking of the automation
and restores normal operation
"SbS" (Step-by-Step) command for
the MASTER barrier
"SbS" (Step-by-Step) command for
the SLAVE barrier
Table 19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M3barM5barM7barL9bar