TROUBLES
The arc striking transformer primary cable has a
poor touch with the power plate. Re-tighten it.
The discharging nozzle is oxidized or is too far.
The fault indicator
Remove the oxidized membrane on the surface of
off, no HF discharge
the discharging nozzle or adjust its distance to be
rustling, and arc
about 1mm.
striking effective
The manual welding argon welding switch is broken.
Replace it. Some components of the HF arc stri-
king circuit is damaged.
Find and replace them.
Large splash of ARC
and very hard in the
Wrong polarity, exchange the polarity of the earth
burning of the
wire and the handle wire.
alkali welding rod
Maybe the over-current protection is activated.
Please switch off the device and then restart it
after the fault indicator is off.
Maybe the over-heat protection is activated. Do not
switch off the device but wait 2-3min, then the
device may naturally restore normal (the device of
pure argon arc welding does not have over-heat
protection function).
The fault indicator
Maybe the inverter circuit is defective. Please plug
on and no output
out the power supply plug of the main transfor-
mer on the MOS plate to restart the device.
1) If the fault indicator is still on, switch off the device
and plug out the power supply plug of the HF arc
striking power supply.
a. If the fault indicator is still on, it will indicate that
some field-effect tubes on the MOS plate are broken.
Find and replace them with the ones of the same type.
EN
SOLUTIONS
Rev. 25.04.2019
70
70
b. If the fault indicator is off, it will indicate that the
voltage
rise transformer in the HF arc striking circuit on the
power supply plate is broken. Replace it.
2) If the fault indicator is off:
The fault indicator
a. Maybe the medium plate transformer is broken. Use
on and no output
an electric bridge to measure the primary inductance
and Q value of the main transformer which should be
L=0.4-0.7Mh.
b. Maybe some the secondary rectifying tubes of the
transformer are punctured. Find and replace with the
ones of the same type.
20. SOLUTIONS AFTER REASONS FOUND
When this device fails or other peripheral components have defects, please
contact the local dealer for maintenance.