Troubleshooting Guide - EINHELL GE-LM 36/4in1 Li Manual Del Usuario

Ocultar thumbs Ver también para GE-LM 36/4in1 Li:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11. Troubleshooting guide

Danger!
Before troubleshooting, switch off the equipment and remove the battery.
The table below contains a list of fault symptoms and explains what you can do to remedy the problem
if your equipment fails to work properly. If the problem still persists after working through the list, please
contact your nearest service workshop.
Problem
The tool does not
work
Tool operates
intermittently
Saw chain is dry
Chain/guide bar
is hot
Cordless
telescoping pole
chain saw judders,
vibrates or does not
saw properly
Anl_GE_LM_36_4in1_Li_SPK7_USA.indb 34
Anl_GE_LM_36_4in1_Li_SPK7_USA.indb 34
EN
Possible cause
- Battery is empty
- Battery is not correctly inserted
- Loose connection (external)
- Loose connection (internal)
- On/Off switch defective
- No oil in the tank
- Vent in the oil tank cap is blocked
- Oil outlet is blocked
- No oil in the tank
- Vent in the oil tank cap is blocked
- Oil outlet is blocked
- Chain is blunt
- Chain is overtensioned
- Chain is undertensioned
- Chain is blunt
- Chain is worn
- Saw teeth point in the wrong
direction
- 34 -
Remedy
- Charge the battery
- Remove the battery and reinsert
(see 5.21)
- Consult a specialist workshop
- Consult a specialist workshop
- Consult a specialist workshop
- Top up with oil
- Clean the oil tank cap
- Clear the oil outlet
- Top up with oil
- Clean the oil tank cap
- Clear the oil outlet
- Re-sharpen or replace the chain
- Check the chain tension
- Adjust the chain tension
- Re-sharpen or replace the chain
- Replace the chain
- Refi t the chain with the teeth facing
in the correct direction