14. INSTALL THE INTERIOR BLOWER (P8D BLOWER MODEL ONLY) (CONT'D)
Make sure the impellers are correctly installed, the insert will not work properly if reversed.
Both impellers are different in the dual blower, one
rotates clockwise and the other counterclockwise.
Each wheel and motor have an arrow and a number
on them, you have to match them correctly (see
drawing beside).
Pass the blower cable through the plastic clamp (A) in the wiring box. Completely tighten the
plastic clamp. See figure beside.
Connect blower cable into wiring box using provided waterproof wire connectors.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1 Strip wires 3/8".
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller
stranded wires slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess
sealant in and around conductors. DO NOT REUSE.
Connect wires as follow: ORANGE to ORANGE (B), WHITE to 2 other WHITE wires (C)
from step 10, and GREEN under ground screw (D). DO NOT FORGET TO CONNECT
THE GROUND. Reinstall the wiring box cover.
15. LIGHT BULBS
This insert must use 120 V, 50 W max., type GU10 shielded halogen lamps, included.
In order to prevent the risk of personal injury, do not install a lamp
identified for use only in enclosed fixtures.
1. Install lamps by placing the bulb leads into their grooves in the socket and gently push
upward and turn clockwise until secured.
2. Install chrome rings by gently pushing upward and turning clockwise until secured.
All manuals and user guides at all-guides.com
CAUTION
HD0023
:
WARNING
!
- 10 -
FRONT
1
VO0084
D
HE0033
HE0078
2
A
Not completely
Completely
tightened
tightened
B
A
C