Gas Connection; Water Connection - Angelo Po FC 611 G Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GAS CONNECTION

Caution - warning
Make the connection in compliance with the relevant le-
gal requirements, using appropriate and recommended
materials.
To make the connection, connect the mains line to the appli-
ance's connection pipe, fitting a shut-off tap (A), to allow the gas
supply to be cut off when necessary.
Important
The tap (A), not supplied with the appliance, must be
installed in an easily accessible position and its sta-
tus (on or off) must be obvious at a glance.
CONNECTING THE BURNT GAS
EXHAUST VENT
Caution - warning
Make the connection in compliance with the relevant le-
IT
gal requirements, using appropriate and recommended
materials.
GB
Connecting to a flue with natural draught.
DE
Connect the appliance's exhaust outlet to the flue (A) using a
line complying with the dimensions shown in the diagram.
FR
Connecting to a fan extractor hood
Position the appliance underneath the hood (B) and connect a
ES
line of the dimensions shown in the diagram to the appliance's
exhaust outlet.
Important
The fan of the extraction system must switch on auto-
matically when the gas supply tap is turned on.
English
A
IDM-3960320170.tif
B
A
IDM-3960320180.tif

WATER CONNECTION

7/8
Caution - warning
Make the connection in compliance with the relevant le-
gal requirements, using appropriate and recommended
materials.
Water supply connection
– Connect the mains line to the appliance's connection pipe, fit-
ting a shut-off tap (B) to allow the water supply to be cut off
when necessary.
Important
The tap (B), not supplied with the appliance, must be
installed in an easily accessible position and its sta-
tus (on or off) must be obvious at a glance.
B
Caution - warning
The appliance must be supplied with drinking water hav-
ing the characteristics shown in the table. If these char-
acteristics are not complied with the appliance might
suffer damage; a water treatment device should there-
fore be installed.
Description
7/9
Pressure
pH
Conductivity
Hardness
Salt and metallic ion content
Chlorides
Sulphates
Iron
Copper
Manganese
Chlorine
- 10 -
7/10
IDM-39603401700.tif
Value
200÷400 kPa (2÷ 4 bar)
7÷7.5
µ
< 200
S/cm
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
< 0,1 mg/l

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fc 1011 g

Tabla de contenido