COMMISSIONING
en
26
O P E R A T I N G I N S T R U C T I O N S | WLG16
Turn the Teach-Turn adjustment (without pressing) to set the desired object mode.
A blue LED lights up according to the set object mode.
Press the Teach-Turn adjustment for about 1 to 3 seconds to set the switching
threshold.
If mode 1 to 4 is selected, the yellow LED lights up when the reflector is in view of
the sensor.
Lead the object into the path of the beam. The yellow LED goes out, meaning the
object is detected and the setting is correct.
With object selection 5, the film must be in the path of the beam when the
potentiometer is pressed. The yellow LED does not light up until the film is no
longer in the beam path. When this has been checked, the setting is correct.
The blue LED of mode M lights up when a setting has been selected via IO-Link
which deviates from the predefined parameter sets of modes 1-5. This mode
cannot be selected directly on the device.
3
4
5
2
1
M
Highly-transparent objects
1
Semi-transparent objects
2
Opaque objects
3
Bottles/trays
4
Check of foil tear
5
M
Manual (specific setting via IO-Link)
8020349.1DS6/2021-11-24 | SICK
Subject to change without notice