Check The Application Conditions; Sensing Range Setting - SICK W16 Serie Instrucciones De Uso

Ocultar thumbs Ver también para W16 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
7.2

Check the application conditions

7.3

Sensing range setting

8020349.1DS6/2021-11-24 | SICK
Subject to change without notice
Figure 7: Alignment
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram [see
figure
8] (x = sensing range, y = operating reserve).
1
0
1.2
2
0
3
0
2.8
4
0
2.5
5
0
3.5
6
0
0
1
2
3
(3.28)
(6.56)
(9.84)
Sensing range
Figure 8: Maximum distance between the sensor and the respective reflector type
Reflector PL10F CHEM
1
Reflective tape REF-AC1000 (50 x 50 mm)
2
Reflector PL10FH-1
3
Reflector PL10F
4
Reflector PL20F
5
Reflector P250F
6
The Teach-Turn adjustment is used to set the object mode and switching threshold,
figure
9,
see figure
10.
The WLG16 is equipped with AutoAdapt technology. The switching threshold is automat‐
ically adjusted in the event of contamination or after cleaning.
4
5
4
5
6
(13.12)
(16.4)
(19.69)
Distance in m (feet)
O P E R A T I N G I N S T R U C T I O N S | WLG16
7
COMMISSIONING
see
25
en

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wlg16 serie

Tabla de contenido