Stylies AQUILA Instrucciones De Uso página 13

Ocultar thumbs Ver también para AQUILA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
a standard descaler and then rinse it thoroughly. Reassemble the device completely before use.
Thoroughly rinse out the water tank on a regular basis.
Replace filter cartridge (8) every 1-2 months as appropriate for the hardness of the water.
FILTER CARTRIDGE AND WATER HARDNESS
The life-span of the cartridge is dependent on the hardness of the water. This can be tested
using the test strip supplied (The test strip is adhered to the reverse side of this instruction
manual).
Dip the test strip into the water for one second.
After approx. one minute, the result can be seen on the measuring strip. Some of the green
areas will change their colour to pink. The number of pink areas corresponds to the hardness
of the water.
Example: If there are three pink areas, the water has a hardness of "3".
Number
of pink
areas
0/1
2
3
4
A simple test can be carried out to determine whether the cartridge is functioning correctly: hold a
small mirror in the steam for a few seconds. If a white deposit has been left on the mirror (a sign of
lime scale), the cartridge needs replacing.
IONIC SILVER CUBE™ (OPTIONAL)
Before attaching the water tank, insert the Ionic Silver Cube™ in the base in the position indicated.
The Ionic Silver Cube™ with its patented technology prevents the growth of bacteria and germs. It
can be used for a maximum of one season, and must be replaced at the start of the next heating
season (i.e. when the weather becomes cold).
Despite using the Ionic Silver Cube™, you should replace the water on a daily basis.
Useful Information:
Information on how an ultrasonic vaporiser works
How does the ultrasonic vaporiser work? An ultrasonic membrane in the interior of the device
causes the water to oscillate, causing very fine droplets of water to be "catapulted off" from the
water surface. These droplets mix with the air in the spray chamber and are then blown into the
room through a ventilator as a visible spray. This fine spray evaporates in the warm air in the room,
moistening the air that people breathe.
White dust:
The ultrasonic vaporiser's method of action causes all substances contained in the water to be
sprayed, including calcium carbonate (a cause of limescale) and minerals. In order to prevent this as
far possible, the water is fed through the filter cartridge before being sprayed. The cartridge retains
a large percentage of the substances contained in the water. Tap water varies greatly from region
to region in terms of its calcium and mineral content. Some minerals cannot be sufficiently filtered
10
Water
Hardness
hardness
(°dH)
soft
ab 4°dH
medium
ab 7°dH
Slightly hard
ab 14°dH
Very hard
ab 21°dH
Cartridge needs replacing
after days/litres
(for 3 litres per day)
approx. 120 days
approx. 360 litres
approx. 60 days
approx. 180 litres
approx. 40 days
approx .120 litres
approx. 20 days
approx. 60 litres

Publicidad

Tabla de contenido
loading

Tabla de contenido