6. Connect a drain valve (sold separately) to
one of the 1/2 in. openings in the tank tee.
(Fig. 6)
WARNING: Not providing a relief valve
can cause extreme overpressure that could
result in personal injury and/or property
damage.
A properly sized pressure relief valve must be
installed on any installation where the pump
pressure can exceed the pressure tank's
maximum working pressure or on systems
where the discharge line can be shut off or
obstructed. The relief valve drain port should be
piped to a drain.
7. Attach the pressure relief valve (sold
separately) to the remaining 1/2 in. opening
in the tank tee. (Fig 7)
8. To connect the pressure tank to the pump,
begin by threading a 1 in. coupling (sold
separately) onto the pipe tee. (Fig. 8)
6
Tape
7
8
Tape
15
IL1156
IL1157
50 60
40
70
30
20
80
10
IL1158