2. NOTE: For each wire coming out of the
pump, including the green ground wire, slide
the wire from the pump into one end of a
metal connector from the splicing kit. Then
slide stripped end of wire from electrical
cable into other end of metal connector.
Connector should be centered over both
wires. Squeeze metal connector until it
closes tightly over both wire ends.
(Fig 2)
3. Slide one shrink tube over each crimped
joint. (Fig 3)
4. Hold a torch (not included) approximately 6
in. from the center of the tubing and move it
back and forth. Heat one set of wiring tubing
at a time until seal is completed. During the
heating process, keep all other wires/tubing
away from heat to prevent melting together.
Avoid overheating, as this may make the
tubing brittle. When liquid oozes from end of
tube, seal should be complete. (Fig 4)
CAUTION: Do not lift pump by power
cable or motor leads! Damage to cable or leads
will result.