2. Thread the electrical wire from pump into
the right opening in the bottom of the control
box and tighten the electric wire strain relief
securely. (Fig. 2)
3. Attach the black, yellow and red wires to the
appropriate terminals marked "B", "Y" and
"R". (Fig. 3)
4. Connect the green ground wire from the
pump to the green ground screw in the lower
right corner of the control box. (Fig. 4)
2
L1
3
L1
L2
4
L1
L2
17
L2
R
Y
B
R
Y
B
R
Y
IL1174
B
IL1175