9. Add additional couplings, unions and pipe (all
sold separately) as necessary to reach the
pump. (Fig. 9)
NOTE: Schedule 80 pipe recommended
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK
WARNING: This equipment is intended for installation by a technically qualified electrician.
Failure to install it in compliance with national and local electrical codes may result in electrical shock
or fire hazard, unsatisfactory performance, and equipment failure.
WARNING: Always disconnect power source before working on or near the pump, its connected
load and wiring. If the power disconnect is out of sight, lock it in the open position and tag to prevent
unexpected application of power.
NOTE: Pump is a 3-wire pump and requires a control box (See chart on page 5). All models require
230-volt service.
1. Remove the cover from the control box (sold
separately) and mount it in an indoor location
protected from moisture. (Fig. 1)
9
Schedule 80 Pipe Shown
1
Terminal
L2
Terminal
L1
L1
Green
Ground
Screw
16
Terminal
R
Terminal
Y
Terminal
L2
R
Y
B
B
Green
Ground
Screw
50 60
40
30
70
20
80
10