Chapter II
5.7.
Diode threshold voltage measurement
Measurable voltages :
Measurement current :
Resolution :
Protection :
5.8.
dB function
Displays measured values in dBm relative to a resistance reference which can be adjusted
from 1 to 9999 ohms and backed up in non-volatile memory (factory-set to 600 ohms, refer
to adjustment procedure in § 4.6).
Resolution :
Absolute error in dB :
Additional computation error :
Measurement range :
Protection :
5.9.
Resistive power function
Displays resistive power relative to a resistance reference which can be adjusted from 1 to
9999 ohms and backed up in non-volatile memory (factory-set to 600 ohms, refer to
adjustment procedure in § 4.6.).
Measured function is :
Resolution :
Accuracy :
Measurement max. voltage :
Protection :
Display unit :
5.10. Frequencies
Selector switch setting :
Measurement range :
Accuracy :
Protection :
Display :
Range
0.62 Hz to 5 kHz*
5 kHz to 50 kHz
50 kHz to 500 kHz
* rectangular signal
Additional positive limit in DC : + 3 % of range, except in 1000 V
and in 10 A
(1.5 A additional)
DC
34
0 to 2 V
1 mA ± 20 %
1 mV
600 V
RMS
0.01 dB
0.09 x V
± 0.01 dB
10 mV
AC
± 1100 V
(measured voltage)
100 µW
2 x V
accuracy (%)
AC
750 V
AC + DC
± 1100 V
VA
V
, mV, V
AC
0.62 Hz to 500 kHz
0.03 %
1100 V
PK
600 V
RMS
600 V
RMS
50 000 points
500 mV
5 V to 500 V
500 µA to 500 mA
2% of range
5% of range
/////////////
10% of range
, can be reset automatically.
relative error as a percent
AC
to 750 V
AC
PK
2
/ Rref
PK
, mA, 10 A
DC
in V
, mV, V
modes
AC
DC
(F1 + F2) in mA mode
(F2) in 10 A mode
SENSITIVITY
750 V
100 V
250 V
/////////////
range (150 V additional)
DC
Portable digital multimeter
10 A
2 A