Release the power trigger to stop the motor.
Lamp indicators in the product
Indication
1 green lamp flashes. The product is connected to a power pack and is pre-
2 green lamps flash.
3 green lamps flash.
3 green and 1 yellow
lamps flash.
3 green, 1 yellow and
1 red lamps flash.
All the status indica-
tion lamps flash.
1635 - 003 - 20.08.2021
Cause
pared for operation.
The power output is less than 70% of the maximum
available output in operation.
The power output is 70-90 % of the maximum available
output in operation.
The cutting speed is at its best performance.
The power output is 90 % of the maximum available out-
put in operation.
The power output drops.
The product is too hot.
The product is too hot.
The power is decreased.
The system is in automatic shutdown.
Push the machine stop button on the power pack.
Refer to the operator's manual for the power pack.
Step
N/A
N/A
N/A
Decrease the load.
Decrease the load or increase
the water flow or airflow to de-
crease the temperature.
Decrease the load or increase
the water flow or airflow to de-
crease the temperature.
Increase the water flow or airflow
to decrease the temperature.
Put the power pack in a location
with lower temperature.
Replace the air filter.