Release the power trigger to stop the motor.
Lamp indicators in the product
Indication
1 green lamp flashes. The product is connected to a power pack and is pre-
2 green lamps flash.
3 green lamps flash.
3 green and 1 yellow
lamps flash.
3 green, 1 yellow and
1 red lamps flash.
All the status indica-
tion lamps flash.
1635 - 003 - 20.08.2021
Cause
pared for operation.
The power output is less than 70% of the maximum
available output in operation.
The power output is 70-90 % of the maximum available
output in operation.
The cutting speed is at its best performance.
The power output is 90 % of the maximum available out-
put in operation.
The power output drops.
The product is too hot.
The product is too hot.
The power is decreased.
The system is in automatic shutdown.
•
Push the machine stop button on the power pack.
Refer to the operator's manual for the power pack.
Step
N/A
N/A
N/A
Decrease the load.
Decrease the load or increase
the water flow or airflow to de-
crease the temperature.
Decrease the load or increase
the water flow or airflow to de-
crease the temperature.
Increase the water flow or airflow
to decrease the temperature.
Put the power pack in a location
with lower temperature.
Replace the air filter.
25