TOP COWLING

TOP COWLING

CHECKING THE WATER DRAIN HOLE

Check:
Water drain hole 1

Obstruction

CHECKING THE TOP COWLING FIT

1. Check:
Top cowling fit

Loose/unlatched
cowling fook.
2. Adjust:
Top cowling hook position

Adjusting steps:
(1)Loosen the bolt 1 approximately 1/4
of a turn.
(2)Move the top cowling hook 2 either
up or down slightly.
NOTE:
Moving the hook toward the seal will

loosen the top cowling.
Moving the hook away from the seal will

tighten the top cowling.
(3)Secure the bolt 1.
Top cowling hook bolt:
5 N
m (0.5 kgf

(4)Check the top cowling fitting and
repeat the adjustment necessary.
3-2
Clean.

Adjust the top

m, 3.7 ft
lb)