Terminal No. Function
1-2-3
Motor
4-5
Flashing light
5-6
AUX
Auxiliary capaci-
7-8
tor
9-10
Courtesy light
11-12
24Vac
13-14
SCA/PhotoTest
15
COM
16
SWO
17
SWC
18
PHOT 1
19
PHOT 2
20
PHOT 3
21
PHOT 4
22
STOP
23
OPEN
24
CLOSE
25
PED
26
Step-by-step
27
COM
28-29
DAS
30-31
Aerial
32-33
2
radio channel
nd
34-35
SAFETY
Selection of
36-37-38
Mains power
supply
Single-phase
39-40
power supply
Three-phase
39-40-41
power supply
THINK Control Unit
INPUT/OUTPUT FUNCTIONS
THINK Control Unit
Description
Connection, 230Vac motor - single-phase:
1-Movement+capacitor/2-Common/3-Movement+capacitor
Connection, 400Vac motor - three-phase:
1-U/2-V/3-W
Check that the voltage selection jumper on terminals 36-37-38 is correctly positioned.
Connection of flashing light, 230Vac 40W max.
Connect a negative electric brake to this output.
WARNING: Output, 230Vac 0,5A max.
Output for pickup auxiliary capacitor. See wire diagram.
Free N.O. contact (2A 150W) to control the Courtesy light which is timed according to the
TLS parameter.
Output, accessory power supply 24Vac/0,5A max
Output, 24Vac/0,5A max. This can be preset as open gate indicator light or as checked
devices power supply (PhotoTest) through the TSTP logic.
In the event of presetting as PhotoTest, please refer to the diagram "Connection of checked
safety devices"
Common for limit switches and photocells
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, Photocell 1 (N.C. contact). It can be disabled in the opening phase, see PHO1 logic.
Input, Photocell 2 (N.C. contact). It can be disabled in the opening phase, see PHO2 logic.
Input, Photocell 3 (N.C. contact). It can be disabled in the opening phase, see PHO3 logic.
Input, Photocell 4 (N.C. contact). It can be disabled in the opening phase, see PHO4 logic.
Input, STOP push-button (N.C. contact)
Input, OPEN push-button (N.O. contact).
Input, CLOSE push-button (N.O. contact)
Input, pedestrian push-button (N.O. contact)
Input, step-by-step (N.O. contact)
Common for all other control inputs.
Input, safety edge contact.
Resistive edge: closed " DAS" jumper.
Mechanical edge: open "DAS" jumper.
When the safety edge is activated, the gate movement stops. The gate movement is re-
versed for approximately 3 sec if the INVA logic is ON. If no safety edge is used: "DAS"
Jumper open, jumper between terminals 28-29.
Connection of the antenna to the receiver extractable board (30-signal/31-screen).
Output, 2
radio channel of the two-channel extractable receiver.
nd
Emergency stop connection. WARNING: Mains power supply.
Remove the jumper and connect a N.C., changeover switch, suited for the mains voltage.
See wire diagram.
Selection of power supply voltage, short-circuit:
36 and 37 for three-phase power supply (400Vac)
37 and 38 for single-phase power supply (230Vac)
Input, single-phase mains power supply 230Vac/50Hz (39-L / 40-N)
Input, or three-phase mains power supply, 400Vac/50Hz (39-R / 40-S / 41-T).