Beninca THINK Manual De Usario página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
MENU
Lack of phase check in case of three-phase power supply is enabled or
disabled.
2pha
On: Check activated.
Off: Check deactivated.
The movement reversion in the event of triggering of the amperometric
sensor or the DAS input is activated or deactivared.
On: Reversion activated. The activation of the edge or the sensor causes
inva
a movement reversion (opening) for approx. 3 sec.
Off: Movement reversion not activated. The activation of the edge or the
sensor causes the immediate stopping of the gate movement.
The motor protection switch is enabled or disabled. Its sensitivity is ad-
justed by SAFM parameter.
Smot
On: amperometric sensor activated.
Off: amperometric sensor deactivated.
The rapid movement reversion is enabled or disabled after the activation
of the photocell in the closing phase.
ON: Rapid reversion activated. The movement reversion time, in the event
doSp
of activation of the photocell, is reduced to approx. 1 sec.
To be used only on light-weight and fast doors.
OFF: Rapid reversion deactivated. The movement reversion time, in the
event of activation of the photocell, is approx. 3 sec.
MENU
The number of the cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed
NMAN
once more, the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
RESET of the control unit. WARNING!: This resets the control unit to the default values.
RES
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button <PG> is
pressed once more, the control unit is reset.
All photocell inputs are short-circuited by default (PHOT1/2/3/4) with the COM terminal. With this presetting, the control unit can
be operated also without photocells.
After connecting and setting the photocells required by the type of system, the inputs which are not in use should be short-circuited
to the inputs in use by copying the settings in the PHOx parameter, as shown hereunder:
1 pair of photocells on input PHOT1, active in the closing phase only:
Logic PHO 1
Logic PHO 2
ON
1 pair of photocells on input PHOT1, active in both opening and closing:
Logic PHO 1
Logic PHO 2
OFF
OFF
1 pair of photocells: active in both opening and closing (PHOT1)
+ 1 pair of photocells: active in the closing phase only (PHOT2):
Logic PHO 1
Logic PHO 2
OFF
14
FUNCTION
IMPORTANT: Photocell inputs not in use
Logic PHO 3
ON
ON
Logic PHO 3
OFF
Logic PHO 3
ON
ON
FUNCTION
Logic PHO 4
RX1
ON
Logic PHO 4
RX1
OFF
Logic PHO 4
RX1
ON
Settable values
ON-OFF-(Default)
(OFF)
(OFF)
(OFF)
(OFF)
JUMPERS
(1)
(2)
(3)
(4)
18
19
20
21
JUMPERS
(1)
(2)
(3)
(4)
18
19
20
21
JUMPERS
(1)
(2)
(3)
(4)
RX2
18
19
20
21
MEMO

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Think-iThink-p

Tabla de contenido