The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure. The vibration emissions may differ
from the specified value, depending on how the power
tool is used. Operating personnel must be protected with
defined safety measures based on the estimated expo-
sure under the actual conditions of use (these must take
into account all phases of the operating cycle, e.g. the
times when the power tool is switched OFF and the times
it is switched ON, but is not under load).
2.4 o
perAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 95% at +10°C not condensed
3.
haNDLINg
3.1 p
rotective devices
The machine may only be operated with
the safety guards and the additional han-
dle fitted!
3.1.1 s
Afety guArd
f
it protective guArd
The bolts and the grooves must align.
A
djustment of sAfety guArd
Bring the safety guard into the desired working position.
For fastening the screw must be tightened down. To re-
lease, turn screw back approx. ½ rotation. Safe operation
is guaranteed only with tightened screw. If the cowl can
no longer be turned with ease, the locking mechanism
must be cleaned.
r
emovAl of sAfety guArd
If necessary, release screw with Allen key. Bring bolt and
groove into alignment and remove the safety guard.
c
leAning of locking mechAnism
Remove safety guard as mentioned above.
/ o
PERaTIoN
Remove clamping nut and backing flange.
Loosen and remove the three clamping screws.
Carefully remove the spring washer with the three balls,
the drive plate and the washer. Thoroughly clean all parts.
Replace defective parts. Lubricate spring disc ball traveler
with a little multi-purpose grease. Refit all parts in reverse
sequence, making sure that the drive plate and spring
washers are correctly aligned (grooves).
Tensioning screws PT3.5x14 are used for tension-
ing the locking mechanism. When carrying out
maintenance work on the safety guard or on the
25