30. Mounting of air separator

Screw the air separator to the furniture door in order to
separate the supply and waste air.

31. Adjusting the door opening angle

Depending on the installation situation, it may be necessary
to adjust the door opening angle. A door opening angle of
115° has been set at the factory.
To adjust the door opening angle to 90°:
Open door to 90°.
Insert the banking pin through the boreholes which are
now vertically aligned and drive in with a hammer.
38

32. Changing the door spring

Rotate the adjusting screw with a cross-head
screwdriver.
I = maximum spring tension
0 = no spring tension
Installation of the appliance is now complete.