Appliancespecific safety instructions
WARNING! TOXIC DUST!
►
Working with the tool can produce harmful/
toxic dusts which represent a health hazard
for the person operating the appliance and
for anyone else in the vicinity .
■
CAUTION: SUPPLY LINES! DANGER!
Ensure that you are not likely to hit power, gas
or water supply lines when you are working
with the power tool . If necessary, check with a
service line detector before you start to cut or
drill into a surface .
■
Collect any dust that may accumulate, e .g . with
a vacuum cleaner .
Residual risks!
Even if you operate this power tool properly, there
will still be residual risks . The following risks can
occur in relation to the power tool's design and
structure:
1 . Lung damage, if no suitable dust protection
mask is worn .
2 . Hearing damage, if no suitable hearing protec
tion is worn .
3 . Damage to health caused by handarm vibra
tions if the appliance is used for extended
periods or is not properly used and maintained .
WARNING!
►
The power tool creates an electromagnetic
field during operation . This field can, in
certain circumstances, impair active or
passive medical implants . To reduce the risk
of fatal injuries, we recommend that people
with medical implants consult their doctor and
the manufacturer of the medical implant
before operating this machine .
Original accessories/auxiliary
equipment
■
Use only the accessories and additional equip
ment that are specified in the operating instruc
tions and are compatible with the appliance .
■
36
│
GB │ MT
Use
WARNING!
►
Switch the appliance off and remove the
power plug before starting any work on the
appliance .
Additional handle
NOTE
►
For safety reasons, you should only use this
appliance with the additional handle
attached .
♦
Loosen the strap on the additional handle
by turning it clockwise .
♦
Push the additional handle
of the quick release chuck
♦
Turn the additional handle
position .
♦
The locking positions on the additional
handle
must now be pushed over the
locking pin on the spindle of the appliance .
♦
Turn the additional handle
again to tighten it .
NOTE
►
Move the additional handle
various locking positions depending on your
working position . Undo and lock the addi
tional handle
as described previously .
Depth stop
♦
Push the locking button for the depth stop
and keep it pushed in .
♦
Insert the depth stop
handle
.
♦
Make sure that the teeth on the depth stop
point upwards and downwards .
♦
Pull the depth stop
between the tip of the drill and the tip of the
depth stop corresponds with the required
drilling depth .
♦
Release the locking button for the depth stop
to lock the depth stop
in the direction
.
to the required
anticlockwise
into the
into the additional
out until the distance
.
PSBM 750 B3