CONTROL PANEL - LEDS (FIG.14)
L1. Setting of current adjustment by remote
control.
L2. Setting of current adjustment from the
front panel.
L3. Setting of visualization of welding volta-
ge on the display.
L4. Setting of visualization of welding current
on the display.
L5. Set welding procedure: LED lights in
TIG, in CV lights simultaneously with L6.
L6. Set welding procedure: LED lights in
MMA, in CV lights simultaneously with
L5.
L7. Welding parameter adjustment, with
knob 2 (red LED on).
L8. VRD function activated in MMA (red LED
on).
L9. Power voltage present (green LED on)
L10. Thermal protection intervention (yellow
LED on)
WARNING: When the yellow LED is
on, do not cut off power from the cur-
rent generator, as this would interrupt
ventilation to the overheated parts.
When the LED goes off, the welding
process may continue.
L11. VRD
L12. On indicates that the display is display-
ing a value in Ampere.
L13. On indicates that the display is display-
ing a value in volts.
L09
L1
L2
L3
L4
L12
L15
L16
L11
L5
L10
L7
L14
L13
L17
Fig.14
L14. On indicates that the display is showing
a percentage value.
L15. Hs: Hot start function (red LED on + letter
H on the display); value can be adjusted
using the knob 2.
L16.AF: Arc force function (red LED on + let-
ter A on the display); value can be adju-
sted using the knob 2.
L17. Iw: Welding current (red LED on), adju-
stable with the knob 2 (from 5A to the
maximum current issued by the genera-
tor) or on the remote control (red LED lw
fl ashing). In this case the maximum current
will be the current set using the knob 2.
L28. Time of gradual current reduction (down-
slope), adjustable with knob 2, "Aut" - 0.0
to 25".
Notes:
- Any adjustments to a welding pa-
rameter are immediately memorized
and made available for welding.
- Five seconds after the last parame-
ter regulation, the generator automati-
cally exits menu confi guration.
L6
L8
EN-11