8.2.6 Changing Parameters at the "Mechanic Level" and the "Special Level" with
the OC-TOP Control Panel
A change in the parameter values is e.g. necessary for the setting of the needle positions
(Chapter 8.2.7) and the setting of the machine-specific parameters (Chapter 8.2.9).
Preparation for activation of the "Mechanic Level (B)".
Turn the mains switch off.
Hold the 5 (P/M) and 6 (T/E) keys pressed and turn the mains switch on.
Release the 5 (P/M) and 6 (T/E) keys, the display shows an "*" (number 11)
between the program number (numbers 9 and 10) and the seam run
(numbers 12 and 13).
Sewing is possible.
Example
Activating the "Mechanic Level (B)"
Prerequisite: Key 5 (P/M) is not lit.
Press the 6 (T/E) key (lit)
With the numbers 10 to 12 a parameter number (the first time 104, thereafter the
last selected) and with the numbers 14 to 16 the corresponding parameter value is
shown.
Sewing is not possible.
Example
Changing the parameter number and the parameter value
The hundreds of the parameter number are changed with the P+ or P- keys.
The tens and ones of the parameter number are changed with the S+ or S- keys.
The parameter value is changed with the L+ or L- keys.