Connection Plugs

120 VAC, 20 Amp, GFCI Duplex
Receptacle
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
ure
2-4. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
NOTE: Limit length of extension cords to fif-
teen feet, or less, to prevent voltage drop and
overheating of wires.
Figure 2-4. 120 VAC, 20 Amp, GFCI Duplex
Receptacle NEMA 5-20R
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
AC at 30 Amps (or greater). See
• CX6500E: Use this receptacle to operate
120 Volt AC, 60 Hz, single phase loads
requiring up to 3240 Watts (3.2 kW) of
power at 27 Amps or 240 Volt AC, 60 Hz,
single phase loads requiring up to 6480
watts (6.4 kW) of power at 27 Amps. The
outlet is protected by two 27 Amp 2-pole
connected toggle circuit breakers.
• CX8000E: Use this receptacle to operate
120 Volt AC, 60 Hz, single phase loads
requiring up to 3600 watts (3.6 kW) of
power at 30 Amps or 240 Volt AC, 60 Hz,
single phase loads requiring up to 7200
watts (7.2 kW) of power at 30 Amps. The
outlet is protected by two 30 Amp push-to-
reset circuit breakers.
6
Fig-
120 VAC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 3-
wire cord set to the plug and to desired load.
The cord set should be rated for 125 Volts AC
at 30 Amps (or greater). See
Use this receptacle to operate 120 Volt AC,
60Hz, single phase loads requiring up to 3600
watts (3.6kW) of power at 30 Amps. The outlet
is protected by a 30 Amp push-to-reset circuit
breaker.
000203
Figure
2-5.

Remove Contents from Carton

1. Open carton completely by cutting each
2. Remove and verify carton contents prior to
Figure 2-5. 120/240 VAC, 30 Amp Receptacle
NEMA L14-30R
Figure 2-6. 120 VAC, 30 Amp Receptacle
NEMA L5-30