Ductwork Installation
5.
Use 6" round aluminum or steel pipe to connect the plastic exhaust on the hood to the
ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6.
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
6.
Connect three wires (black, white and green) to house wires and cap with wire
connectors.
7.
Connect according to color: black to black, white to white, and green to green.
8.
Test the operation of the hood before moving on to next step. Make sure power is
supplied to the hood.
Mounting
Screws
Figure 5
Figure 6
6