ENGLISH
14) CENTRAL PROGRAMMING (fig.A)
14.1) PARAMETER MENU (PARAM)
PARAMETER
MIN
MAX
0
60
TCA
1
99
CLEAR T.
0
127
ZONE
partial ope-
10
70
ning
chemist ope-
3
30
ning
0
6
door mode
radar se-
0
2
tup
0
3
emerg. e ntry
0
3
buzzer
type of
0
5
lock
door sta-
0
1
tus
1
90
alarm time
1
10
accel.
1
10
brake
op. d ist.
10
70
decel
cl. d ist.
10
70
decel
op. d ist.
1
20
sloud
cl. d ist.
1
20
sloud
4
99
op speed
4
99
cl speed
1
99
OP. T ORQUE
1
99
CLS. T ORQUE
INSTALLATION MANUAL
DEFAULT
4
Automatic closing time [s]
30
Clearance Time [s]
Zone []
0
Sets the zone number of the door included in the serial connection for commands via central controllers.
Partial opening [%]
50
Adjusts partial opening percentage compared to total opening in "Partial open" mode.
Chemist's opening [cm]
12
Centimetres the door opens by in "Chemist's open" mode.
0
Door mode []. Sets the door's operating mode (Sect. 15.1)
Radar mode []. Sets the radars' operating mode (Sect. 15.2)
0
0
Emergency mode []. Sets the EMERGENCY input operating mode (Sect. 15.5)
0
Buzzer mode []. Sets the buzzer's operating mode (Sect. 15.3)
Lock mode []. Sets the locking device's operating mode (Sect. 15.4)
0
Door state output mode []. Sets the DOOR STATE output's operating mode (Sect. 15.7)
0
30
Once the set time is up, if photocells are triggered, the ALARM contact is closed (Sect.15.6)
Acceleration ramp [] (fig.C rif.A)
Sets door acceleration at start (1=min., 10=max.). The autoset feature sets this parameter automatically. Should
5
this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported
by the buzzer emitting a continuous beeping sound), during which obstacle detection is not enabled.
Deceleration ramp [] (fig.C rif.B)
Sets the door's deceleration for intermediate stopping (not at travel limit). (1=min., 10=max.). The autoset featu-
5
re sets this parameter automatically. Should this parameter be edited, it will be followed by a complete opening/
closing cycle for setting purposes (reported by the buzzer emitting a continuous beeping sound), during which
obstacle detection is not enabled.
Opening deceleration space [cm] (fig.C rif.C)
Sets the distance needed for the door to move from high to low speed during an opening operation.
50
The autoset function automatically sets this parameter..
Any modification to this parameter will be followed by a complete setting manoeuvre (identified by a continuous
buzzer beep), during which obstacle recognition is not active.
Closing deceleration space [cm] (fig.C rif.D)
Sets the distance needed for the door to move from high to low speed during a closing operation.
50
The autoset function automatically sets this parameter.
Any modification to this parameter will be followed by a complete setting manoeuvre (identified by a continuous
buzzer beep), during which obstacle recognition is not active.
Opening approach distance [cm] (fig.C rif,E)
2
Sets the approach distance to reach the opening travel limit. This distance is travelled at low speed.
Closing approach distance [cm] (fig.C rif.F)
2
Sets the approach distance to reach the closing travel limit. This distance is travelled at low speed.
Running speed during opening [%] (fig.C rif.G)
Sets the running speed that the door must reach during opening, as a percentage of the maximum speed the
60
actuator can reach. The autoset feature sets this parameter automatically. Should this parameter be edited,
it will be followed by a complete opening/closing cycle for setting purposes (reported by the buzzer emitting a
continuous beeping sound), during which obstacle detection is not enabled.
Running speed during closing [%] (fig.C rif.H)
Sets the running speed that the door must reach during closing, as a percentage of the maximum speed the
60
actuator can reach. The autoset feature sets this parameter automatically. Should this parameter be edited, it
will be followed by a complete opening/closing cycle for setting purposes (reported by the buzzer emitting a
continuous beeping sound), during which obstacle detection is not enabled.
Opening torque [%]
Sets sensitivity to obstacles during opening (1=max., 99=min.) The autoset feature sets this parameter auto-
75
matically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to
obstacles.
Closing torque [%]
Sets sensitivity to obstacles during closing (1=max., 99=min.) The autoset feature sets this parameter auto-
75
matically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to
obstacles.
DESCRIPTION
- 21
VISTA SL - Ver. 01