13) ARIA CONTROL BOARD
13.1) TERMINAL BOARD WIRING (Fig.23)
WARNINGS - When performing wiring and installation, refer
to the standards in force and, whatever the case, apply good
practice principles.
The wires carrying a very low safe voltage (24V) must be kept physically
separate from low-voltage wires, or they must be suitably insulated with at
least 1mm of additional insulation. Wires must be secured with additional
fastening near the terminals, using devices such as cable clamps.
13.2) FACTORY CONNECTIONS (Fig.24A)
TERMINAL
DESCRIPTION
JP2-JP4
Power supply unit wiring
JP2= brown
JP4= white/blue
JP7-JP8
Gearbox wiring
JP7=brown
JP8=white/blue
JP12
Encoder wiring
JP19
Solenoid lock wiring
20
- VISTA SL - Ver. 01
INSTALLATION MANUAL
13.3) USER CONNECTIONS (Fig.24B)
TERMINAL
L
N
JP18
JP10
1
2
3
4
5
6
7
8
9
10
11
12-13
14-15
16-17
18-19-20
DESCRIPTION
PHASE
NEUTRAL
EARTH
Universal palmtop programmer connector
Connector for additional optional boards
Controllers common
OPENING PHOTOCELL (NC) input
CLOSING PHOTOCELL (NC) input
STOP (NC) input
INT. RADAR control (NO) input
EXT. RADAR control (NO) input
OPEN KEY (NO) input

EMERGENCY input

Control common
OPENING PHOTOCELL FAULT (NO) input
CLOSING PHOTOCELL FAULT (NO) input
24V~ VSAFE 180mA max output
Power supply to devices with checking function.
Serial RS485.
14 = A
15 = B
Connection to external programming devices.
Controllers common
Connection of remote door in cage mode
24V~ 500mA max output
Power supply to radar controls, photocells or other
devices.
"Door status" output
18 = NO (voltage-free contact)
19 = COM (voltage-free contact)
20 = NC (voltage-free contact)